CRESTRON GREEN LIGHT™ Architectural Dimming
Introduction
CRESTRON GREEN LIGHT architectural dimming cabinets come pre-configured with GLX architectural dimming
and switching modules already installed. In addition, branch circuit breakers come preinstalled and prewired to the
modules. The cabinets only require installation and wiring of feed and load circuits.
Industry Compliance
The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
(E227280 (cabinet) and E103692 (modules))
Application
The following diagram shows CRESTRON GREEN LIGHT architectural dimming cabinets in a lighting application
that is controlled by an IPAC system.
CRESTRON GREEN LIGHT Architectural Dimming Cabinets in a Typical Lighting Application
Crestron Electronics, Inc. Installation Guide – DOC. 6688A
15 Volvo Drive Rockleigh, NJ 07647 (2020963)
Tel: 888.CRESTRON 02.09
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Application

CRESTRON GREEN LIGHT™ Architectural Dimming Introduction CRESTRON GREEN LIGHT architectural dimming cabinets come pre-configured with GLX architectu

Page 2 - Physical Description

Architectural Dimming CRESTRON GREEN LIGHT™ To power the modules externally from a Cresnet 24 VDC power supply, connect the external power supply t

Page 3

CRESTRON GREEN LIGHT™ Architectural Dimming Testing Manual Control A lighting module can be manually controlled from its front panel. Switch Function

Page 4 - Installation

Architectural Dimming CRESTRON GREEN LIGHT™ Save Override Settings The state of each output can be saved as an override setting, which can be autom

Page 5

CRESTRON GREEN LIGHT™ Architectural Dimming Problem Solving Troubleshooting The following table provides corrective action for possible trouble situa

Page 6 - MLO BREAKER DETAIL

Architectural Dimming CRESTRON GREEN LIGHT™ Appendix A: Setting Module Net IDs The following procedure will normally be performed by an authorized

Page 7 - Wire Gauge and Torque Values

CRESTRON GREEN LIGHT™ Architectural Dimming Appendix B: Module Specifications Specifications for the GLXP modules are listed in the following table.

Page 8

Architectural Dimming CRESTRON GREEN LIGHT™ Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned fo

Page 9 - POWER Port Wiring

Architectural Dimming CRESTRON GREEN LIGHT™ Physical Description This section shows the exterior and interior dimensions of the CRESTRON GREEN LIGH

Page 10 - OVERRIDE Port Wiring

CRESTRON GREEN LIGHT™ Architectural Dimming Interior Dimensions of CRESTRON GREEN LIGHT Architectural Dimming Cabinets (GLE-XXX-Xx2, left; GLE-XXX-Xx

Page 11 - Testing

Architectural Dimming CRESTRON GREEN LIGHT™ Installation Observe the following when installing the cabinet: • The cabinet must be mounted by a lic

Page 12 - Save Override Settings

CRESTRON GREEN LIGHT™ Architectural Dimming Wiring NOTE: All wiring must be installed in accordance with all local and national electrical codes. N

Page 13 - Problem Solving

Architectural Dimming CRESTRON GREEN LIGHT™ Feed Wiring (Section A) Feed Wiring for MLO and MCB Applications MCB BREAKER DETAILMLO BREAKER DETAIL&

Page 14 - Changing the Net ID

CRESTRON GREEN LIGHT™ Architectural Dimming Load Wiring (Section B) CAUTION: Bypass jumpers are provided on each output to allow testing and to prot

Page 15

Architectural Dimming CRESTRON GREEN LIGHT™ The GLX-DIMFLV8 also requires wiring the terminals for 0-10 VDC control wire. Refer to the following di

Page 16 - Return and Warranty Policies

CRESTRON GREEN LIGHT™ Architectural Dimming Connector Wiring REDWHITEBLUEBLACKREDWHITEBLUEBLACKOVERRIDE:FROM OTHER CABINET; FROM ALARM, ETC. (OPTIONA

Comments to this Manuals

No comments